Flow measurement applications are very diverse and each. Inserttype venturi flow meter installation and operation. Reducer vortex extends the measurable flow range, reduces installation costs, and minimizes project risk. Vortex shedding flow meters are widely used for measuring the liquid flow rate in a single phase flow. Flow monitors vortex shedding flowmeter description this flowmeter is made for water, waterglycol coolant of low viscosity fluids.
Browse online, or one of our applications engineers can help you choose the right product for your application. Options for a 0 to 5 vdc or a frequency output proportional to the volumetric flow rate are also available. More specifically, proposed application examples have included tracking of a moving dipole, 35 flow sensor, 12, 3638 a vortexshedding flowmeter. Emco engineering measurements companydro flow series of vortex flowmeters are designed specifically for flow water measurement. A vortex flow meter works based on the principle of karman vortex street demonstrated in the below figure this principle essentially means that when an obstruction is placed in path of a flow, it can produce a series a vortices alternating from each side of the obstruction. These flow meters operate on the karman vortex principle and measure the flow velocity of liquids. The rvl series vortex shedding flow meter is a generalpurpose electronic liquid flow meter. In this flow, vortices are created at the back of the body and detach periodically from either side of the body.
Vortex shedding flow meter and temperature transmitter shop now. Flow meter resources flow meter application advisor. Metering of fluids at high velocities with vortex shedding flowmeters. In a vortex flow meter, an obstruction in the flow path, often referred to as a shedder bar, serves as the bluff body. Our vortex flow meters offer added safety with a leakfree design and robust construction. Oct, 2011 in selecting the size of all flowmeters, we want to get the normal flow into the center of the range. Yokogawas classic vortex flow meter is sil approved, and sil 2 approval can be obtained with a dual meter design for redundant use. Vortex flow meters flow instrumentation badger meter. Fv200 series plastic vortex flow meter for corrosive liquids. Thermal mass meter a mass flowmeter consisting of two rtd temperature probes and a heating element that measure the heat loss to the flowing mass.
A mass flow meter consisting of specially formed tubing that is oscillated at a right angle to the flowing mass of the fluid. Flanged card, triclamp, thread, flange, insertion, temperature and pressure compensation. Flow monitors plastic vortex shedding flow rate transmitters description the p420. The rngrwgrwbg series vortex shedding flow meter family is designed to provide accurate and repeatable gas flow measurement. Compact vortex flow meter without moving parts mass flow online. A vortexshedding flowmeter based on ipmcs request pdf. An everyday example of a vortex shedding phenomenon is a flag waving in the breeze. As fluid moves across a vortex meter shedder bar, vortices form.
Pdf design and development of 16 inch vortex flow meter with. If liquids or condensate can be present in the flow, the meter should be installed so that liquids will not accumulate on the ultrasonic transducers the small buttons on either side of the vortex strut. The three wire version power supplied separate from the. The thermister is excellent sensing method when mounted on front face where very. Vortex shedding flow meter operating under the same principle of the vortex shedding measurement, this type of vortex flow meter is suitable for viscous,clean, or dirty waterlike liquids that are compatible with brass, pvdf, and fkm.
Advanced predelivery programming and calibration is included, so. These applications are found in most process industries, including rubber, steel, fabrication, manufacturing, refining, paper, chemical, food. Meter installation the labeling of the flow direction on the meter should be aligned with the flow in the pipe. The proper method of installing a halmi venturi meter 2 caution. Vortexmaster fsv430, fsv450 vortex flowmeter abb group. If the cylindrical structure is not mounted rigidly and the frequency of vortex shedding matches the chimneys constructed of thinwalled steel tube can be sufficiently flexible that, in air flow with a speed in the critical range, vortex shedding can drive the chimney into violent oscillations that can damage or destroy the chimney. The flow meters ability to measure low viscosity liquids and volumetric flow rate makes it a great choice for water or condensate measurement. This flow meter vortex shedding phenomenon is true for both gases and liquids. These applications are found in most process industries, including rubber, steel, fabrication, manufacturing. This creates a pressure on a sensor body containing a piezoelectric crystal. Utility vortex flow meter designed for general purpose, clean fluids and steam flow applications starting at. Universal cp 34 inchflow range 300600 gpm 162271 lpmmax pressure 200 psi bar f l o w m o n i t o r s coolpoint with rotatable enclosure this fl owmeter is made for water, waterglycol coolant or low viscosity fl uids.
More specifically, proposed application examples have included tracking of a moving dipole, 35 flow sensor, 12, 3638 a vortex shedding flowmeter, 39 and a turbulent flow sensor. The frequency that the vortexes are shed depend on the size and shape of the body. Volume flow measurement is enough for substances with small variations in density such as liquid. May 02, 2020 compact liquid flow meter without moving parts. Vortex flow meter rvl series vrxds01586en03 may 2015 product data sheet description the rvl series meter uses vortexshedding technology for repeatable flow measurement accurate to 1 percent of full scale. Wolfgang uses a pendulum partially immersed in a makeshift flow tank to show us the effect of vortex shedding on a small object. Add to mydirectindustry favorites requestbuttons catalog excerpts. Plastic vortex meters cx series open email download. Interestingly the flow meter vortex shedding effect can be seen to occur in everyday life. In fluid dynamics, vortex shedding is an oscillating flow that takes place when a fluid such as air or water flows past a bluff as opposed to streamlined body at certain velocities, depending on the size and shape of the body. The fv101 series comprises inline flow meters that use the vortex shedding measuring principle.
Titan discuss flow meter vortex shedding if you place an obstruction such as a bluff body in a fluid stream vortices will be formed downstream of the impediment. Vortex flow meters have been appreciated by users as volume flow meters, which can, in principle, be applied to any flow measurement of liquid, gas, or steam. Flow meter manuals, drawings, certifications, and other documents. Port sizes available from 38 three eighths inches to 2 two inches in diameter. Equation 3 also shows that the flow rate can be measured independently of the fluid pressure, temperature, density and viscosity. Install meter in the pipe line so that the flow directional arrow agrees with the direction. Vortex shedding was one of the causes proposed for the failure of the original 1 a thrill ride, vertigo at cedar point in sandusky, ohio suffered vortex shedding during the winter of 2001, causing one of the three towers to collapse. The maximum flow rate is governed by the meter pressure loss typically two velocity heads, the onset of cavitation with liquids, and sonic velocity flow choking with gases. Vortex shedding flow meter performance at high flow. It is ideal for applications where low maintenance costs are important. A flow meter is a device used to measure the flow rate or quantity of a gas or liquid moving through a pipe. Working principle of vortex flow meter instrumentationtools.
Compact vortex flow meter without moving parts mass flow. As shown in picture, in the meter body vertical insert a triangular prism root. However, compensations for temperature and pressure are necessary when measuring volumetric flow and mass flow rate in the reference standard state. Vortex shedding flow meter for low viscosity fluids starting at. Three vortex shedding cycles or 300 ms, whichever is greater. Dpf30 series two stage batch controllerratemeter shop now.
The standard output is a two wire loop powered 420 ma current. The frequency of the vortices shedding is proportional to the fluid velocity. For a vortex meter to work, you must have a minimum reynolds number of 10,000 coanda units go lower. If the arrangement is symmetrical the swirls will be shed from alternate sides of the obstruction. The frequency of the vortices is proportional to the flow velocity. The frequency of alternating of these vortices is proportional to the flow rate being obstructed. When fluid flows around a cylindrical object, there is a range of. The vibrating frequency of the vortex shedding is related to the velocity of the flow.
The flapping of a flag is probably the most common example of this effect. Vortex shedding flow meter and temperature transmitter. Minimum required backpressure is 10 psig at maximum flow and at 70 f 21 c. Vortex flow meters use an obstruction, known as a bluff body, in the flow stream to create downstream vortices which are alternately formed on either side of the bluff body.
Maximum flow ranges from 4200 gpm 15750 lpm temperature. Industrial vortex flow meters suitable for flow rate or flow totalization measurements, industrial grade and for use with many fluid types. Vortex flowmeter flange card type vortex flowmeter tempersturepressure compensaton type vortex flowmeter inserted type vortex flowmeter sanitaryclamp type lugbtype 2 vortex flow sensor measuring the flow of liquid of steam,gas and low viscosity relationship. Higher backpressures are required at elevated temperatures and occasional surges to 125% of maximum flow. Vortex flow meters are used to measure the flow of liquids andor gases and are best suited for turbulent flow with a reynolds number greater than 10,000. Therefore, your meter is oversized, as average flow is near the minimum detectable.
The optimal pitch for vortex shedding is a 5d pitch 5 x the diameter of the stack. Vortex shedding flowmeter universal flow monitors pdf. Since the early nineties vortex shedding flowmeters are used in the process. Vortex flow meters operate under the vortex shedding principle, where an oscillating vortexes occur when a fluid such as water flow past a bluff as opposed to streamlined body.
The fv101 series can be used with nonviscous, clean, or dirty waterlike liquids that are compatible with brass, pvdf, and fkm. Vortex shedding flowmeters vortex meter information formquestionnaire use this questionnaire to find the right vortex meter for your application. The fluid strikes a bluff body, imparting alternating vortices downstream of the bluff. Vortex flowmeters, also know as vortex shedding flowmeters or oscillatory flowmeters, measure the vibrations of the downstream vortexes caused by a barrier in the moving stream. The piping system must create some backpressure on the meter to allow vortex formation and to prevent cavitation, especially at full flow. What links here related changes upload file special pages permanent link page.
The meter has no moving parts, and any potential for fluid contamination is eliminated by the corrosionresistant all plastic. With builtin temperature compensation as a standard feature and optional integral pressure compensation, it is the first choice for saturated steam, superheated steam and compensated gas flow measurement. Jun 22, 2012 wolfgang uses a pendulum partially immersed in a makeshift flow tank to show us the effect of vortex shedding on a small object. Vortex flow meters are flow sensors that detect the frequency of vortices shed by a bluff body placed in a flow stream. The vortex shedding frequency around a bluff body can be calculated as.
Flow monitors vortex shedding flowmeter and temperature transmitter ct 142 inch flow and temperature transmitter maximum flow ranges from 4200 gpm 15750 lpm max pressure 300 psi 20 bar temperature range 32210f 299c flow temp coolpoint with rotatable enclosure viton is a registered trademark for dupont performance elastomers. These meters employ a patented ultrasonic technique to measure a form of turbulence created in the flow. A market leading process measurement device, the versaflow vortex shedding flow meter is designed with steam and gas applications in mind. These chimneys can be protected from this phenomenon.
The versaflow vortex shedding flow meter is a twowire design that is available in configurations for pipe line sizes from dn15 to dn100 12 to 4 in a wafer design and dn15 to dn300 12 to 12. The meter minimum flow rate is established by a reynolds number of 10,000 to 10,500, the fluid density, and a minimum acceptable shedding frequency for the electronics. Flow monitors vortex shedding flowmeter and temperature transmitter ct 142 inch flow and temperature transmitter maximum flow ranges from 4200 gpm 15750 lpm max pressure 300 psi 20 bar temperature range 32210f 299c flowtemp coolpoint with rotatable enclosure viton is a registered trademark for dupont performance elastomers. Cx series coolpoint vortex shedding flowmeter installation and operation manual universal flow monitors, inc. Vortex flowmeter is a flowmeter for measuring fluid flow rates in an enclosed conduit. The rvl series vortexshedding flow meter is a generalpurpose electronic liquid flow meter. Applications for liquid, dry gas, wet gas, wet steam, saturated steam and superheated steam. The shedding of these vortices due to the flow forms a vortex trail. Mass flow online offers a new series of liquid flow meters. As these vortices are shed from the bluff body, they create.